Automatic Chemistry Analyzer
Automatic Chemistry Analyzer

price: $0.00


Automatic Chemistry Analyzer

The automated biochemical analyzers featured here represent two different classes of multi-parameter analytical systems. One class features systems for use in clinical settings ranging from small office and veterinary clinics to high throughput clinical laboratories. The other type of automated biochemical analyzer is configured for bioreactor monitoring. Both automated biochemistry analyzers offer a wide range of test templates for common substances, with analyzers directed toward nutrient and bioreactor byproduct detection. An automated biochemistry analyzer can focus on analytes, such as drugs of abuse, electrolytes, specific proteins, as well as enzyme and metabolite tests for renal, cardiac, and liver function. These automatic biochemistry analyzers offer a hierarchy of options and functions such as number of photometric or ISE tests per hour (up to 240 and 400 per hour respectively), as well as the number of ISE test and assay types available. Automatic biochemical analyzer systems allow one to switch between on-line and off-line analysis of nutrient and by-product concentrations.

 

Characteristics

  • Best for middle or small size hospital
  • Closed integrated photovoltaic systems, no mechanical parts, maintenance free
  • Small reaction volume, cost saving
  • Discrete, random access, automatic
  • Random choice of method, the real discrete automatic chemistry analyzer
  • This automatic chemistry analyzers have gained a lot of national patents during the researching.
  • Independent mixing probe
  • Reduce the reagent consumption
  • Easy to operate: Friendly and Intellective Software
  • Accurate results: Avoid operative error/random error
  • Test speed:  200-300Test/Hour, less waiting time
  • Sample Tray:  60 Unfixed Positions for various samples
  • Sample Consume:  2ul-50ul, with High precision Syringe
  • Needle cleaning:  It can reduce the across-contaminated
  • Washing system:  Self-washing in time with test.
  • Mixing Needle:  Self-mixing the reaction liquid
  • Liquid Sensor:  Self-detecting of the liquid level, tracing the rest volume
  • Quality Control Test:  Insert QC at any time, 6 QC types for a project

 

Technical Specifications

System Functions

  • Analysis Method: end-point, kinetic, two-point,double-reagent, double-wavelength, multi-standard etc, open to various reagents

Sample/ReagentsHandling

  • Sample volume: 1-50µl,0.5µl step
  • Sample dilution: automatic/Manual pre-dilution, with dilution ratioup to 1:100
  • Reagent position; 26pcs(with refrigeratedfunction, 2-8℃)
  • Reagent Volume:180-600µl, 1µl step

Reaction System

  • Reaction Cuvette: 60 pcsmade of special material
  • Optical Length of Cuvette:6mm
  • Reaction Volume: 150~400µl
  • Reaction Time: 8-12minutes
  • Reaction Temperature:37±0.1℃

Optical System

  • Light Source:halogen-tungsten lamp
  • Wavelength: 300-800nm, 8wavelengths, precision ±2nm
  • Absorbance Range: 0~3.0Abs
  • Resolution: 0.001Abs
  • Rear spectrophotometry

Calibration

  • Calibration:linear/nonlinear multi-points calibration
  • Re-test: retest thesample automatically when the resultis out ofthe linearity range or the sample is not sufficient

Working Condition

  • Power Supply: 100-240V,50/60Hz, ≤350W
  • Temperature: 10-35℃
  • Humidity: ≤90%, no dew

Input and Output

  • Input: RS-232interface/computer
  • Output: multi-format printout

Sample/Reagent Position

  • 18pcs sample position
  • 26pcs reagent position
  • Reagent refrigerated function

Reaction Cuvettes

  •  60 pcs reusable cuvettes
  • Automatic blanktesting for cuvette
  • Colorimetry system in the patternof lightsplitting behind cuvette
  • Dismountable,easily replacement

Sample/Reagent/Mixing Probe

  • Automatic liquid leveldetect
  • Collision protectionfunction
  • Probe internal/externalwashing
  • Clot detection function
  • Independent mixing probe

7-Step Auto Cleaning System

  • Automatic 7-step washing
  • Hi-tech washing stationto ensure accurate results
  • With low waterconsumption: 1-2L/H

Intellectivesoftware

  • Automatic washingcuvette when startup & shut down
  • Automatic detect reagentvolume during every startup
  • Show reagent platetemperature during every startup

Optimum calibration cuvette

  • Automatic Cuvette blank testing
  • Automatic wash selected cuvettes
  • Real-time online monitoring running status ofcuvette

Dynamic and Real-time display of running status

  • Real-time online monitoring running status ofsample tray, reagent tray cuvette
  • Real-time online monitoring reagents residualvolume
  • Real-time onlinemonitoring waste volume

Automatic dilute and re-test

  • Automatic dilute andre-test when absorbance range is out of range
  • Automatic dilute andre-test when linear limit is out of range
  • Automatic dilute andre-test when linear range is out of range
  • Two modes(nodilute and auto dilute) are available
  • Freely set the autodilute ratio and dilute water position